Applications
Blow molding machines for pharmaceutical bottles
HDPE, LDPE and PP bottles for pills, capsules, oral liquids and eye drops, on multi-cavity molds with accurate necks.

Containers
Bottles for medicine and health products
Pharmaceutical bottles are small, made in large numbers and closed with child-resistant or induction-sealed caps, so neck accuracy and weight consistency matter.
- Pill, tablet and capsule bottles
- Oral liquid and syrup bottles
- Eye-drop and nasal spray bottles
- Vitamin and supplement bottles




Engineering
Consistency is the product
A pharmaceutical bottle is not difficult to blow. A 100 ml HDPE pill bottle is one of the simplest containers on a blow molding machine: round, thin-walled, no handle, no barrier. What is difficult is making the ten-thousandth bottle identical to the first, because the filling line, the capper and the QC department all work to tolerances that a household bottle never sees.
Three things have to be held. Weight, because the wall thickness and therefore the moisture barrier depend on it, and because a 5% weight drift on a 30 g bottle is a visible change in the hand. Neck dimensions, because the cap and the induction seal are validated against a specific bore and thread. And appearance, because a black speck in a white bottle is a rejected batch, not a cosmetic flaw.
That changes the machine specification in ways that are not obvious from the container size. The screw has to run a stable melt temperature, because weight drift usually starts as a temperature drift. The die head has to be easy to purge, because a colour or grade change on a pharma line is a documented event. And the machine has to be able to hold a cycle without operator intervention, because a weight trend is easier to control when nothing else changes.
Cleanliness is the fourth. Most pharma containers are not made in a clean room, but the packing area often is, and the machine has to be able to sit next to it: closed loop cooling rather than an open tank, no oil mist on the mould, and a conveyor that can be covered.
Range
Container range and what it demands
| Container | Typical weight | Neck | Wall | What decides the design |
|---|---|---|---|---|
| 10 – 30 ml eye drop or dropper | 6 – 12 g | 18 – 20 mm | 0.7 – 0.9 mm | Bore tolerance; tip fit |
| 30 – 60 ml syrup bottle | 12 – 22 g | 24 – 28 mm | 0.8 – 1.0 mm | Weight consistency; neck squareness |
| 60 – 120 ml pill or capsule bottle | 18 – 30 g | 33 – 38 mm | 0.9 – 1.1 mm | Moisture barrier; cap torque |
| 120 – 250 ml oral liquid | 28 – 45 g | 38 mm | 1.0 – 1.2 mm | Weight ±2%; sealing land |
| 250 – 500 ml | 40 – 65 g | 38 – 43 mm | 1.1 – 1.4 mm | Top load in a carton; weight tolerance |
| Diagnostic or reagent bottle | 20 – 50 g | 28 – 38 mm | 0.9 – 1.3 mm | Chemical resistance; colour consistency |
Typical values for white HDPE with a tight weight tolerance (±2% is a common specification).
Selection
Choosing the machine by container size
Production cycles for HDPE, including extrusion, blow and cooling. Small pharma bottles are light, so the cycle is short and the cavity count does most of the work.
| Container | Model | Die heads × stations | Shot weight | Cycle | Output per hour |
|---|---|---|---|---|---|
| 10 – 30 ml dropper | KSY45-J1.8L | 4 × 2 = 8 | 0.05 – 0.10 kg | 16 – 22 s | 1,300 – 1,800 |
| 30 – 60 ml syrup | KSY50-J2L | 4 × 2 = 8 | 0.10 – 0.18 kg | 18 – 24 s | 1,200 – 1,600 |
| 60 – 120 ml pill bottle | KSY55-J2.5L | 3 × 2 = 6 | 0.11 – 0.18 kg | 22 – 28 s | 770 – 980 |
| 120 – 250 ml oral liquid | KSY65-J3L | 2 × 2 = 4 | 0.11 – 0.18 kg | 26 – 32 s | 450 – 550 |
| 250 – 500 ml | KSY75-J6L | 2 × 2 = 4 | 0.16 – 0.26 kg | 30 – 38 s | 380 – 480 |
Output = 3,600 ÷ cycle × containers per cycle, calculated. A tighter weight tolerance than ±2% usually costs a cavity or a few seconds.
Where a pharma customer asks for a lower cavity count than the table suggests, the reason is usually traceability rather than output: fewer cavities means a defect can be tied to a mould position more easily, and a weight trend is easier to see on four cavities than on eight.
Process
The process window
| Parameter | Typical setting | What goes wrong outside it |
|---|---|---|
| Melt temperature | 190 – 205 °C, held within ±3 °C | Drift shows up first as weight drift, then as a dimensional change |
| Mould temperature | 10 – 15 °C, controlled per circuit | Uneven circuits give one cavity heavier than another |
| Blow pressure | 0.4 – 0.6 MPa, regulated | Wandering pressure changes the wall without changing the setting |
| Regrind | Segregated, fixed ratio, recorded | Free regrind changes the colour and the weight |
| Purge and grade change | Documented procedure | Black specks in a white bottle reject the batch |
| Ambient | Stable; the machine away from doors and draughts | Draught on the parison gives a weight trend through the shift |
The most useful pharma-specific habit is statistical rather than mechanical: weigh the first five bottles from every cavity at the start of a shift, and every hour after that, and plot it. A drift of 0.3 g an hour is invisible in the hand and obvious on the chart, and it is usually the first sign that a heater band or a thermocouple is going.
Quality
Tests that decide acceptance
| Test | What it proves | Where it typically fails |
|---|---|---|
| Weight by cavity, hourly | The wall is inside ±2% and not drifting | One cavity running light |
| Neck bore and thread gauge | The cap and the induction seal fit | Ovality after blowing |
| Leak / seal integrity | No leakage after capping | Sealing land flatness |
| Drop, filled | The bottle survives packing and transport | Base corner |
| Top load in the carton | The carton stack does not deform the bottle | Shoulder |
| Visual against a limit sample | No specks, flashes or colour drift | Seam and base |
Troubleshooting
Defects and where they come from
| What you see | Usual cause | What to change first |
|---|---|---|
| Weight drifts through the shift | Barrel or die-head temperature drifting; draught on the parison | Check the heater bands, then shield the parison |
| One cavity heavier | Uneven die-head flow or a colder circuit | Balance the circuits, check the profile per head |
| Black specks in a white bottle | Degraded material in the head or the regrind bin | Purge, inspect the head, segregate regrind |
| Cap will not torque | Neck oval, or the thread is worn in the insert | Check insert cooling and wear |
| Seal leaks after induction | Sealing land not flat | Check pin concentricity, then the insert face |
| Colour shifts between batches | Regrind ratio not fixed | Run a gravimetric blend, record the ratio |
Line
Line configuration and a worked example
| Item | Specification for a 100 ml pill bottle line |
|---|---|
| Blow molding machine | KSY55-J2.5L, Ø55 mm screw, three die heads, double station |
| Mould | Three cavities, chrome-plated, neck insert with separate cooling |
| De-flashing | Cut against the mould; no hand trimming in a pharma area |
| Leak testing | Sample per batch, plus a 100% check if the closure is critical |
| Conveyor | Covered, feeding a bagging station next to the clean area |
| Cooling | Closed loop chiller; no open tank next to a clean area |
Worked example: a 100 ml pill bottle at 22 g, six cavities, 25 s cycle. Shot weight is 6 × 0.022 = 0.13 kg, so the plasticising demand is 0.13 ÷ 25 s = 19 kg/h, inside the 48 kg/h of the KSY55-J2.5L. Output is 3,600 ÷ 25 × 6 = 864 bottles an hour.
If the specification is ±1% by weight rather than ±2%, the practical response is not a slower cycle but a tighter process: a fixed regrind ratio, a shielded parison and hourly weighing. Cutting the cavity count is the last resort, because it costs output without improving the root cause.
Reference
Where to read next
For the material behaviour HDPE or PP; for the wall-thickness method uneven wall thickness; for the output arithmetic how to calculate blow molding output. The container families are on the case studies index.
Recommended
Machines and molds for this application
See it running
Small medicine bottles in production
Small bottles are made on a multi-cavity mold; the control panel sets temperatures and the cycle.
FAQ
Questions
What tolerance can you hold on bottle weight?
±2% is a normal specification for a pharma container, and ±1% is achievable with a stable process: fixed regrind ratio, shielded parison, hourly weighing by cavity. The limit is usually the process discipline, not the machine.
Do pharmaceutical bottles need a clean room?
The blow molding itself usually runs outside a clean room; the packing area is the classified space. What the machine has to offer is closed-loop cooling, no oil mist on the mould and a conveyor that can be covered.
Which machine for a 100 ml pill bottle?
KSY55-J2.5L with three die heads on a double station, six bottles a cycle at 22 – 28 s, or the KSY50-J2L with four heads where the output matters more than the cavity count.
Why does the weight drift during a shift?
Almost always a temperature drift, in a heater band, a thermocouple or the ambient air around the parison. It is worth plotting weight by hour: a 0.3 g drift is invisible in the hand and obvious on the chart.
Can you supply the mould with a specific neck finish?
Yes, the neck insert is made to the closure drawing. The bore, the thread and the sealing land are the three dimensions that matter, and they are all in the insert rather than in the machine.
Is regrind allowed?
Only where the customer's specification allows it, and then segregated and at a fixed ratio. In pharma the record of the ratio matters as much as the ratio itself.
How do you handle a colour or grade change?
As a documented procedure: purge the barrel and the head, scrap the transition, and restart with a fresh weight check by cavity. Black specks are the defect that ends a batch, so the purge is not shortened.
Do you supply leak testing?
Yes, as line equipment. Sampling per batch is normal; 100% testing is used where the closure is critical or the product is a liquid that must not leak in transit.
Get a quote
Send us your container
Send the drawing or a photo with volume, weight and material, and the output you need. We recommend the machine and mold.
- WhatsApp+86 135 2855 6448
- E-mailsales@kesyer.com